Conformity assessment
There are a couple of options for how conformity assessment can be done. The options vary depending on product category.
The procedures for conformity assessment are described in ANNEX VIII. There are 3 procedures for conformity assessment.
Module A: conformity based on internal control.
Module B+C: EU-type examination.
Module H: conformity based on full quality assurance.
Default category
- Can follow Module A (internal control).
- Can also follow Module B+C & H
Important products Class I
- Can follow Module A, if harmonized standards have been applied or if free and open source and technical documentation is public.
- Can also follow Module B+C & H
Important products Class II
- Can follow Module A, only if free and open source and technical documentation is public.
- Can also follow Module B+C & H
Critical products
- Can follow Module B+C, unless European cybersecurity certification scheme is made mandatory in accordance with Article 8.
- Can also follow Module H
Module B+C involves examination of the product by a notified body. In Module H, the manufacture shall put a full quality assurance system in place. The quality system need approval from a notified body. See ANNEX VIII for more details.